9.2 Monitor Mode (MON)
The inverter boots up in the Monitor Mode (MON). The inverter’s operating conditions can be
monitored at the Monitor Mode display. A maximum of four items can be displayed.
Monitor Mode Setting Details
CNF-20
AnyTime Para
CNF-21
Monitor Line-1
CNF-22
Monitor Line-2
CNF-23
Monitor Line-3
Select items to display in the Monitor Mode display. Monitor mode is the first displayed
mode when the inverter is powered on. A total of four items can be displayed
simultaneously. These include the AnyTime parameter (upper right corner of LCD) and
Monitor Lines -1, -2 and -3. Parameters CNF-20~23 all share the same setting options
as listed in the table below.
During stop, displays the set frequency. During operation,
displays the actual output frequency (Hz).
During stop, displays the set speed (rpm). During
operation, displays the actual operating speed (rpm).
Displays inverter power consumption.
Displays DC bus voltage within the inverter.
Displays input terminal status of the terminal block.
Starting from the right, displays P7–P1.
Displays output terminal status of the terminal block.
Starting from the right,
Q1, Relay5 <- Relay1.
Displays the input voltage value at terminal V1 (V).
Displays input voltage terminal V1 value as a percentage.
If -10V, 0V, +10V is measured,
-100%, 0%, 100% will be displayed.
Displays input voltage terminal V2 value (V).
Displays input voltage terminal V2 value as a percentage.
Displays input current terminal I2 value (A).
Displays input current terminal I2 value as a percentage.
Displays output of PID controller.
Displays reference value of PID controller.
Displays feedback value of PID controller.
Displays the set Date (AP3-01).
Displays the set Time (AP3-02).
Displays the set day (AP3-03).
Selecting 1(Yes) initializes CNF-20–23.