Parameter Descriptions
123
890053-00-02
If MOT-07 (motor rated voltage) is set to 0’, the inverter corrects the output voltage based on the
input voltage in the stopped condition. If the output frequency is higher than the base frequency
and the input voltage is lower than the MOT-07 setting, the inverter will output a voltage based on
the input voltage. The default settings are 230V, 460V or 575V based on the inverter rating.
Group
Code
Name
LCD Display
Parameter Setting
Setting Range
Unit
MOT
07
Motor rated voltage
Rated Volt
0, 170-480 (V),
525-600 (V)
170-480
525-600
V
5.2.3 MOT-09 Trim Power %
When viewing “Output Power”, use Trim Power % (MOT-09) to scale the displayed power when
compared to measured power.
Group
Code
Name
LCD Display
Parameter
Setting
Setting Range
Unit
MOT
09
Trim Power
display
Trim Power %
100 (%)
70-130
%
If the output power displayed on the keypad is lower than expected, increase the set value at MOT-09
(Trim Power %). If the output power displayed on the keypad is higher than expected, decrease this
set value. The output power display is calculated using voltage and current. Use MOT-09 to correct
the error that may occur when the power factor is low.
5.2.4 MOT-10 Power Source - Voltage and Frequency
Set inverter supply (input) voltage. The Low voltage fault level changes automatically based on the set
voltage in MOT-10.
Group
Code
Name
LCD Display
Parameter
Setting
Setting
Range
Unit
MOT
10
Input power voltage
AC Input Volt
240V
240
170240
V
480V
480
320480
600V
575
446-660
Select the frequency of input power. When the frequency is set to 50 Hz, the frequencies set for
60 Hz (including the maximum frequency and base frequency) will change to 50 Hz. Likewise,
changing the input frequency setting from 50 Hz to 60 Hz will change all related settings from 50
Hz to 60 Hz.
Group
Code
Name
LCD Display
Parameter
Setting
Setting
Range
Unit
BAS
10
Input power frequency
60/50 Hz Src
0
60Hz
01
-