Sensorless Vector Control
248
890053-00-02
Code
Keypad Display
Description
Setting Range
Factory Default
Units
Filter
CON-53
Torque Lmt Src
Torque Limit setting
options
0
Keypad-1
0:Keyypad-1
-
1
Keypad-2
2
V1
4
V2
5
I2
6
Int 485
7
FieldBus
9
Pulse
10
V3
11
I3
CON-54
FWD +Trq Lmt
Forward direction
retrograde torque limit
0-200%
180% [4]
%
CON-55
FWD -Trq Lmt
Forward direction
regenerative torque limit
0-200%
180.00%
%
CON-56
REV +Trq Lmt
Reverse direction
regenerative torque limit
0-200%
180.00%
%
CON-57
REV -Trq Lmt
Reverse direction
retrograde torque limit
0-200%
180.00%
%
7.2.1 Sensorless Vector Control Operation for PM motor
To operate a PM synchronous motor in sensorless vector control mode, set DRV-09 (Control
Mode) to 4 (PM Sensorless), select the motor capacity at MOT-01 (Motor Capacity), and enter the
appropriate parameters in the motor (MOT) group with the motor specification values found on the
motor’s name plate. If a specific motor capacity does not exist in the setting options, select a
higher motor capacity that is closest to the actual motor capacity.
Code
Keypad
Display
Description
Setting Value
Setting Range
Units
DRV-09
Control Mode
Control mode
4: PM Sensorless
0~4
-
MOT-01
Motor
Capacity
Motor capacity
Depends on the motor
capacity
1~20
(1HP-125HP
-
MOT-02
Base Freq
Base frequency
Depends on the motor
capacity
30~180
Hz
MOT-03
Pole Number
Motor pole number
Depends on the motor
capacity
2~48
-
MOT-05
Rated Curr
Rated motor
current
Depends on the motor
capacity
1.0~1000.0A
A
MOT-07
Rated Volt
Motor-rated
voltage
Depends on the motor
capacity
170~480V
V
MOT-10
AC Input Volt
AC input voltage
170~528V
V
DRV-20
Max Freq
Max
Depends on the motor
capacity
40.00~180.00Hz
Hz