Parameter Descriptions
204
890053-00-02
PRT-42
ETH 1 min
The 1 minute trip level. The amount of current that can be continuously
supplied to the motor for 1 minute, Percentage is based on the motor-rated
current (MOT-05).
PRT-43
ETH Cont
Sets the amount of continuous rated current (including service factor)
with the ETH function activated. The range below details the set values
that can be used during continuous operation without tripping.