Preparing the Installation
890053-00-02
Voltage
kW
HP
Ground Wire
Input/Output Power Wire
mm
2
AWG
mm
2
AWG
R/S/T
U/V/W
R/S/T
U/V/W
110
150
50x2
1x2
70x2
70x2
1/0 x2
1/0 x2
300
300
132
200
50x2
1x2
95x2
95x2
2/0 x2
2/0 x2
400
400
160
250
50x2
1/0 x2
95x2
95x2
4/0 x2
4/0 x2
70x2
185
300
70x2
3/0 x2
120x2
120x2
250 x2
250 x2
95x2
250
400
95x2
300 x2
185x2
185x2
350 x2
350 x2
315
500
60x4
150x2
2/0 x4
185x2
185x2
350 x2
350 x2
400
650
95x4
200x2
4/0 x4
120x4
400x2
120x4
400x2
250 x4
800 x2
250 x4
800 x2
500
800
120x4
350x2
4/0 x4
750x2
185x4
630x2
185x4
630x2
350 x4
1500 x2
350 x4
1500 x2
Voltage
kW
HP
Ground Wire
Input/Output Power Wire
mm
2
AWG
mm
2
AWG
R/S/T
U/V/W
R/S/T
U/V/W
575V
5.5
7.5
2.5
14
2.5
2.5
14
14
7.5
10
12
14
12
11
15
10
12
10
15
20
4
10
4
4
10
10
18.5
25
6
8
4
6
8
8
22
30
10
8
6
10
8
8
30
40
6
10
8
6
37
50
16
4
16
16
4
4
45
60
16
25
4
4
55
75
25
35
3
2
75
100
25
3
50
50
1
1/0
90
125
35
2
70
70
2/0
2/0
Signal (Control) Cable Specifications
Terminals
Wire thickness
1)
mm
2
AWG
P1P7/CM/VR/V1/I2/24/TI
0.331.25
1622
AO1/AO2/CM/Q1/EG
0.332.0
1422
A1/B1/C1/A2/C2/A3/C3/A4/C4/A5/C5
0.332.0
1422
S+, S-, SG
0.75
18
1) Use STP (shielded twisted pair) cables for signal wiring.