19
890053-00-02
Installing the Inverter
575V: 7.5 HP ~ 40 HP (5.5 kW ~ 30 kW)
575V: 50 HP ~ 125 HP (37 kW ~ 90 kW)
Figures in this manual are shown with covers removed to show a more detailed view of the
installation arrangements. Install covers before operating the inverter. Operate the product
according to the instructions in this manual.
Do not start or stop the inverter using a magnetic contactor installed on the input power
supply.
If the inverter is damaged and loses control, the machine may cause a dangerous
situation. Install an additional safety device such as an emergency brake to prevent these
situations.
High levels of current draw during power-on can affect the system. Ensure that correctly
rated circuit breakers are installed to operate safely during power-on situations.
Line Reactors can be installed to improve the power factor. Note that reactors may be
installed within 32.8 ft (10 m) from the power source if the input power exceeds 600 kVA.