Metasys-N2: If the COM-02 Int485 Proto setting is Metasys-N2, the
communication speed is fixed to 9600 bps and COM-03 Int485 BaudR
is not shown.
Set a communication configuration. Set the data length, parity check
method, and the number of stop bits.
8-bit data / no parity check / 1 stop bit
8-bit data / no parity check / 2 stop bits
8-bit data / even parity / 1 stop bit
8-bit data / odd parity / 1 stop bit
If the COM-02 Int485 Proto setting is Metasys-N2, the communication
frame composition is fixed to D8/PN/S1 and COM- 04 Int485 Mode is
not visible.
Set the response time for the slave (inverter) to react to the request
from the master. Response time is used in a system where the slave
device response is too fast for the master device to process. Set this
parameter to an appropriate value for smooth master-slave
communication.