Linear, Squared, User V/Hz
MMC - Multi-Motor Control
(1) 0–10 V, (1) 0/4–20 mA, Switch selectable to 0–10 Vdc
(7), Select PNP (Source) or NPN (Sink) mode. NO/NC selectable. Functions
of the digital inputs are set with parameters IN-65 through IN-71.
Forward/Reverse Operation
Reset
External Trip
Emergency Stop
Output Disable (Bx)
Jog
Fixed Speed - Step Freq's
Run Enable/Disable (Safety)
3-Wire Control Select
Damper Monitor and Control
2nd Source - HOA/LOR
Up/Down Operation
Analog Hold
PID Disable
Jog Start FWD/REV
Pre-Excite
Timer Input
Fire Mode
Event Timer
Pre-Heat
0–32 kHz, Low Level: 0–0.8 V, High Level: 3.5–12 V
N.O.: Less than AC 250 V, 2A, DC 30 V, 3A
N.C.: Less than AC 250 V, 1A, DC 30 V, 1A
(4)Programmable
relays (Form A)
N.O.: Less than AC 250 V, 5 A
Less than DC 30 V, 5 A
(1) open collector
terminal
AO1: 0(4) - 20 mA, Switch selectable to 0–10 Vdc
AO2: 0-10VDC
Frequency, Current, Voltage, Power, DC Bus Voltage, Fixed, more.