Technical Specifications
377
890053-00-02
Brake Torque 100% (Normal Duty)
Brake Torque 150% (Heavy Duty)
VFD Brake Resistor Specification
VFD Brake Resistor Specification
HP
Benshaw VFD Part
Number
Internal
Brake
IGBT
Resistor
(Ω)
Wattage [W]
(%ED=5%)
Wattage [W]
(%ED=10%)
Resistor
(Ω)
Wattage [W]
(%ED=5%)
Wattage [W]
(%ED=10%)
7.5
VFD-RSI-007-H2-61
Yes
160.0
700
1400
100
1100
2200
10
VFD-RSI-010-H2-61
Yes
120.0
900
1800
80
1400
2800
15
VFD-RSI-015-H2-61
Yes
80.0
1400
2800
54
2000
4000
20
VFD-RSI-020-H2-61
Yes
60.0
1800
3600
40
2700
5400
25
VFD-RSI-025-H2-61
Yes
48.0
2400
4800
32
3400
6800
30
VFD-RSI-030-H2-61
No
40.0
2800
5600
27
4000
8000
40
VFD-RSI-040-H2-61
No
30.0
3600
7200
20
5400
10800
50
VFD-RSI-050-H2-6C
No
24.0
4500
9000
16
6800
13600
60
VFD-RSI-060-H2-6C
No
20.0
5400
10800
13
8400
16800
75
VFD-RSI-075-H2-6C
No
16.0
6800
17600
11
10000
20000
100
VFD-RSI-100-H2-6C
No
12.0
9000
18000
8
14000
28000
125
VFD-RSI-125-H2-6C
No
10.0
11000
22000
7
17000
34000
If the ED% is increased to 10%, the rated capacity (W) of the brake resistor must be doubled.
Related parameter: PRT-66 (ED%) Range 0 - 30%.
Output Relays (OUT-31~ OUT-35 can be set to (25): DBWarn%ED which toggles the output
when duty cycle is exceeded.