47
890053-00-02
Installing the Inverter
Disabling the Built-in EMC Filter
240V: 75 HP ~ 125 HP (55 kW ~ 90 kW)
480V: 150 HP ~ 800 HP (110 kW ~ 500 kW)
Follow the instructions listed below to disable the EMC filters for the H2 inverters with the above ratings.
Remove the front cover located at the top of the inverter. NOTE: With 400 HP and larger inverters, the LCD
cable is connected to the back of the cover and will need disconnected.
Remove the EMC ground cable from the right terminal (EMC filter-ON / factory default) and connect it to
the left terminal (EMC filter-OFF / for power sources with asymmetrical grounding).
240V: 75 HP ~ 100 HP (55 kW ~ 75 kW) 240V: 125 HP (90 kW)
480V: 150 HP ~ 200 HP (110 kW ~ 132 kW) 480V: 250 HP ~ 300 HP (160 kW ~ 185 kW)
480V: 400 HP (250 kW) 480V: 500 HP ~ 800 HP (315 kW ~ 500 kW)