62
Nyquist C4000 User Guide
playing in time type zones not equal to the specified zone, those queued pages will continue to play,
along with the manual tone to the specified zone.
If a specific zone is specified, the dashboard message will use the following format:
Tone (<station_extension> -> <zone_name>): <tone_name>
For example:
Tone (100 -> Library): Chime
Routine triggers that use the Tone or Scheduled-Tone trigger types do not include a zone filter, thus
tone-based routine triggers are activated whenever a tone is played to any zone. The routine trigger
does include a filter for the tone being played, so you can filter routine execution by the tone being
played.
Zone Control: Volume and Audio Distribution Panel
The Zone Control feature presents a simple user interface for controlling volume and audio distributions
from any Windows or Android tablet or mobile device that supports the Google Chrome, Microsoft
Edge, or Apple Safari browser. Small devices such as touch-screen tablets can be used to operate Zone
Control via the browser.
The Zone Control feature can be used to perform the following:
Change volume of Audio Distributions and Paging Zones
Start and stop Audio Distributions
In addition, it has its own configuration settings view. It has two display page views:
Settings / Zone Filter view (see Figure 49, “Zone Control Settings and Zone Filter View,” on page 64)
Zone View, including an Audio Distribution view (see Figure 50, “Zone Control Zone View,” on
page 67).
Initial Setup and Settings
The Zone Control feature does not use the same login model as the Nyquist application. All users share
the same password, specified as Zone Control Password in the System Parameters Page. The first time a
user logs in, they will be directed to the Settings page for initial setup.
To perform the initial user setup:
1 Using a Chrome, Edge, or Safari web browser, enter:
https://<server>/zone-control/login
where <server> is replaced with the IP Address of your Nyquist server.
Important: Before accessing this page, you must install and trust the Bogen Certificate Authority
(CA), as described in "Bogen Digital Certification Authority” on page 129.
2 Enter a new username that has not previously been used.