SERVICE MODE
S-75
F00-300-32
BODY °C
Indicates the machine internal temperature measured by the environment
sensor.
Remarks Same as the reading under DISPLAY > ANALOG
BODY %
Indicates the machine internal humidity measured by the environment sensor.
Remarks Same as the reading under DISPLAY > ANALOG
BODY g
Indicates the machine internal humidity absolute value (g) measured by the
environment sensor.
Remarks Same as the reading under DISPLAY > ANALOG
<<<ZONE-A>>>
Indicates the zone in which the setting shown is effective.
EL-N1
Effective in plain paper mode and, in addition, when copying on a one-
sided copy or on the 1st side of a two-sided copy.
Settings range
–5 ~ +1 (Standard: -2)
Unit: 0.5 kV
EL-N2
Effective in plain paper mode and, in addition, when copying on the 2nd
side of a two-sided copy.
Settings range
–5 ~ +1 (Standard: -2)
Unit: 0.5 kV
EL-OHP
Effective in OHP mode.
Settings range
–5 ~ +1 (Standard: -2)
Unit: 0.5 kV
<M> <S> <R> <P> <F>
ADJUST
DISP
FUNC
COUNTER
OPTION
TEST
HV-EL 2/4
EL-T1
xxxx
EL-T2
xxxx
EL-S1-2
xxxx
EL-S2-1
xxxx
EL-UT1
xxxx
EL-UT2
xxxx
EL-OHP
xxxx
EL-#
xxxx
EL-N1
xxxx
<<<<<<< ZONE A >>>>>>>
EL-N2
xxxx
EL-S1-1
xxxx
EL-S2-2
xxxx
EL-S3-1
xxxx
EL-S3-2
xxxx
BODY
BODY
BODY
xxx
xxx
xxx
˚C
%
g