EasyManua.ls Logo

Canon CLC5000 - Page 698

Canon CLC5000
757 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COPYRIGHT
©
2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-109
Details of SHV
No.
1
2
3
4
High-voltage output
Primary C charging assembly, grid C output,
auxiliary high-voltage Y (–350 µA), develop-
ing bias CDC (–370 V) output
Primary M charging assembly, grid M output,
auxiliary high-voltage Y (–350 µA), develop-
ing bias MDC (–370 V) output
Primary Y charging assembly, grid Y output,
auxiliary high-voltage Y (–350 µA), develop-
ing bias YDC (–370 V) output
Primary K charging assembly, grid K output,
auxiliary high-voltage Y (–350 µA), develop-
ing bias KDC (–370 V) output
Control
Transfer lifter DOWN, photosensitive drum
motor ON, pre-exposure ON, primary C out-
put, grid C output (500 V), auxiliary high-
voltage output C (–350 µA), developing bias
CDC (–370 V) output IB
(Waits for a stop command, or 60 sec.)
Primary C output, grid C output (500 V), aux-
iliary high-voltage output C (–350 µA), de-
veloping bias CDC (–370 V) output OFF, pre-
exposure OFF, photosensitive drum motor
OFF
Transfer lifter DOWN, photosensitive drum
motor ON, pre-exposure ON, primary M out-
put, grid M output (500 V), auxiliary high-
voltage output M (–350 µA), developing bias
MDC (–370 V) output IB
(Waits for a stop command, or 60 sec.)
Primary M output, grid M output (500 V),
auxiliary high-voltage output M (–350 µA),
developing bias MDC (–370 V) output OFF,
pre-exposure OFF, photosensitive drum motor
OFF
Transfer lifter DOWN, photosensitive drum
motor ON, pre-exposure ON, primary Y out-
put, grid Y output (500 V), auxiliary high-
voltage output Y (–350 µA), developing bias
YDC (–370 V) output IB
(Waits for a stop command, or 60 sec.)
Primary Y output, grid Y output (500 V), aux-
iliary high-voltage output Y (–350 µA), devel-
oping bias YDC (–370 V) output OFF, pre-
exposure OFF, photosensitive drum motor
OFF
Transfer lifter DOWN, photosensitive drum
motor ON, pre-exposure ON, primary K out-
put, grid K output (500 V), auxiliary high-
voltage output K (–350 µA), developing bias
KDC (–370 V) output IB
(Waits for a stop command, or 60 sec.)
Primary K output, grid K output (500 V),
auxiliary high-voltage output K (–350 µA),
developing bias KDC (–370 V) output OFF,
pre-exposure OFF, photosensitive drum motor
OFF

Table of Contents