- 133 -
2.2.8 Paper Detecting Commands
ESC c 3 n
CT-S280 CT-S300 CT-S2000 CT-S4000 BD2-2220 PMUseries
Supportmodel
CT-S281
CT-S310 CT-S801/851 CT-S601/651 CT-P29x series CT-S310II
[Function] Selecting thePaperSensor valid fora Paper-end signal output
[Code] <1B>H<63>H<33>H<n>
[Range] 0≤n≤255
[Outline] [The specification which is commontothemodel]
• This command selects by which Paper Sensor aPaper-end signal should be output. Each bit for “n” has the
following meaning:
Value
Bit Position
0 1
0
Paper Near-end Disabled Enabled
1
Paper Near-end Disabled Enabled
2
Paper-end Disabled Enabled
3
Paper-end Disabled Enabled
4
Undefined — —
5
Undefined — —
6
Undefined — —
7
Undefined — —
[Caution] [The specification which is commontothemodel]
•Thiscommandis valid onlyfor the parallel interface.
[Default] [The specification which depend on the model]
CT-S280/CT-S281/CT-S300/CT-S310/CT-S2000/CT-S4000
BD2-2220/PMU series
n=15
CT-P29x series/CT-S301II
n=15 (no signal atpapernear enddue tono paper near endsensor.)
CT-S801/CT-S851/CT-S601/CT-S651
•MSW3-2 OFF: n=15
•MSW3-2 ON : n=12