- 301 -
fn=12: Function 12 Sending the Set Communication Conditions
GS ( E pL pH fn a
[Code] <1D>H<28>H<45>H<pL><pH><fn><a>
[Range] (pL+pH×256)=2 (pL=2,pH=0)
fn=12
1≤a≤4 (Does not send in other thanspecified range)
[Outline] [The specification which is commontothemodel]
•Sends communication conditionsofserial interface specifiedby“a”.
Hex. No. of Data
Header
37H 1
ID
33H 1
Kind ofcommunication conditions (a)
31H(“1”) to34H(“4”) 1
Separationnumber
1FH 1
Set value
30Hto39H 1 to 6
NULL
00H 1
•Setvalue
a=1: At specificationof baud rate
Baud Rate d1 d2 d3 d4 D5 d6
1200◎ 49(“1”) 50(“2”) 48(“0”) 48(“0”) - -
2400 50(“2”) 52(“4”) 48(“0”) 48(“0”) - -
4800 52(“4”) 56(“8”) 48(“0”) 48(“0”) - -
9600 57(“9”) 54(“6”) 48(“0”) 48(“0”) - -
19200(Default) 49(“1”) 57(“9”) 50(“2”) 48(“0”) 48(“0”) -
38400 51(“3”) 56(“8”) 52(“4”) 48(“0”) 48(“0”) -
●57600 53(“5”) 55(“7”) 54(“6”) 48(“0”) 48(“0”) -
●115200 49(“1”) 49(“1”) 53(“5”) 50(“2”) 48(“0”) 48(“0”)
◎---support by CT-S280,CT-S281,CT-S2000,CT-S4000,CT-S801,CT-S851,CT-S601,CT-S651,CT-S310II
●---support by CT-S280,CT-S2000, CT-S4000,PMUseries,CT-P29xseries,CT-S310II
(PMU2XXX does not support 57600bps.CT-P29x series does not support 115200bps)
a=2: At specificationof parity
d1 Parity Setting
48
Noparity
49
Odd parity
50
Even parity
a=3: At specificationof flow control
d1 Flow Control
48 DTR/DSR
49 XON/XOFF
a=4: At specificationof data length
d1 Setting DataLength
48
7-bit length
49
8-bit length