[Function] Executing themacro
[Code] <1D>H<5E>H<n1><n2><n3>
[Range] 0n1255
0n2255
0n31
[Outline] [The specification which is commontothemodel]
Executing contents defined inmacro.
n1 :The number oftimes of macro execution
n2 :Waiting time on macro execution:Waitingtime ofn2 x100msec is given for every execution.
n3 :Macroexecutionmode
n3= 0Continuous execution: The Macro is executed n1 times continuouslyatthe time interval
specified byn2.
n3= 1Execution byFEEDSwitch: After waiting for thetimespecifiedbyn2,the ARARM LEDflickers
and theFEED switch is waiting to bepressed. Whenitispressed,
the macro is executed once.Thisaction isrepeated n1times.
[Caution] [The specification which is commontothemodel]
When thiscommandis received while in macro definition,suspensionof macro definitionis
indicated.At this time, thedefined content iscleared.
No executiontakes place whenthe macro is held undefined.
While inmacro executionwith n3 =1,paper feed withthe FEEDswitch is notavailable.
When MSW2-3ONSpoolprintvalid is specified, n2 isinvalid.