EasyManua.ls Logo

Citizen CT-S280 - Printer Function Setting Commands

Citizen CT-S280
454 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 192 -
2.2.16 Printer Function Setting Commands
GS ( D pL pH m [a1 b1] ... [ak bk]
CT-S280 CT-S300 CT-S2000 CT-S4000 BD2-2220 PMUseries
Supportmodel
CT-S281
CT-S310 CT-S801/851 CT-S601/651 CT-P29x series CT-S310II
[Function] Enabling or disabling real-time command
[Code] <1D>H<28>H<44>H<pL>< pH>< m> [<a1><b1>] [<ak><bk>]
[Range] 3(pL+pH×256)65535
M=20
a=1
b=0, 1, 48, 49
[Outline] [The specification which is commontothemodel]
Enables/disables thefollowing real-time commandprocessing.
a b Function
0,48
Does notprocessDLE DC4fn mt (fn=1). (Invalid)
1
1,49
Processes DLEDC4fn mt (fn=1). (Valid)
pLandpHsets thenumber ofbytesonandafter min (pL+ pH×256).
asets thekindofreal-time command.
bsets Valid orInvalid.
When data raw that meets thecode configuringreal-time commandin theimage data, itis recommended
that the real-time command beset toinvalid by this command.
[Default]
a Type of Real-time Command Initial Value
1 DLE DC4 fn m t (fn=1): Real-time output of pulse specified Valid
[Caution] [The specification which is commontothemodel]
PMU2XXXII/PMU2300III
Among PMU series, only PMU2xxxx type II and III support this function.

Table of Contents

Other manuals for Citizen CT-S280

Related product manuals