- 187 -
GS C ; n1 ; n2 ; n3 ; n4 ; n5 ;
CT-S280 CT-S300 CT-S2000 CT-S4000 BD2-2220 PMUseries
Supportmodel
CT-S281
CT-S310 CT-S801/851 CT-S601/651 CT-P29x series CT-S310II
[Function] Setting the numbering counter mode (B)
[Code] <1D>H<43>H<3B>H<n1><3B>H<n2><3B>H<n3><3B>H<n4><3B>H<n5><3B>H
<n1>,<n2>,<n3>, <n4>,<n5> are character codes.
[Range] 0≤n1,n2,n5≤65535
0≤n3,n4≤255
[Outline] [The specification which is commontothemodel]
•Thiscommandsets thenumbering(serial number counter)mode anda counter value.
n1:Counter default
n2:Counter final value
n3:Counter step value
n4:Identical counter print count
n5:Counter start value
n1<n2:Count-up system
n1>n2:Count-down system
n1=n2orn3= 0or n4=0 :Counter stop
[Caution] [The specification which is commontothemodel]
•Ifthen5 counter start value isbeyondthe counter range specified withn1 andn2,it isassumedto
be n1=n5.
•Ifeachvalue ofn1 through n5 contains the character codeother than “0” through “9”, theprinterwill
invalidate the data up tothat parameter and handle thesubsequent data asnormal data.
[Default] n1=1,n2=65535,n3=1, n4=1,n5=1
[See Also] GS C0,GSC 1, GSC 2, GSc