- 195 -
fn=3: Function 3 Setting Memory Switch Value
GS ( E pL pH fn [a1 b18...b11] ... [ak bk8...bk1]
[Code] <1D>H<28>H<45>H<pL><pH><fn>[<a1><b18>…<b11>]…[<ak><bk8>…<bk1>]
[Range] 10≤(pL+pH×256)≤65535
fn=3
b=48, 49, 50
CT-S280/BD2-2220
a=1, 2, 3
CT-S300
a=1, 2, 3, 4
CT-S281/CT-S310/CT-S2000/CT-S4000/PMU2XXX/PMU2XXXII
CT-P29x series
a= 1,2, 3, 4, 5
CT-S801/CT-S851/CT-S601/CT-S651/CT-S310II
a=1, 2, 3, 4, 5, 6
PMU2300III
a=1, 2, 3, 4, 5, 11, 12
[Outline] [The specification which is commontothemodel]
•ChangestheMSW set in ato thevalue set in “b”.
B Function
48
Sets corresponding bit to OFF.
49
Sets corresponding bit to ON.
50
Does notchange corresponding bit.
[Caution] [The specification which depend on the model]
CT-S281/CT-S310/CT-S2000/CT-S4000/CT-S801/CT-S851
CT-S601/CT-S651/ PMU series
• MSW7 to MSW10 cannot be changed by this command. They can be changed by the
setting of customize value.