4.2.4 MSW4
MSW4-1: Automatic length measurement
[Outline] In selecting black mark paper, set the enable/disable of automatic length measurement.
(Blackmark/labelsupport model only)
OFF(0) ON(1)
BM Measure Invalid Valid
ON(1) OPERATION: Automatic length measurementisenabled.
Atpower-up, measurementoperationistaken.
OFF (0) OPERATION:Automatic length measurementisdisabled.
Operation follows thevalue set by <GSl>.
MSW4-2: Black mark sensor position
[Outline] Selects black mark sensor position.
OFF(0) ON(1)
BM sensor position surface back
ON(1) OPERATION: Black mark sensor detectsa black mark on theprintingsurface.
OFF (0) OPERATION:Black mark sensor detectsa black mark on theprintingback.
MSW4-2 Searching top of form at power on.
[Outline] Set the enabled/disabled of the function to search the top of form at power on.
OFF(0) ON(1)
Power on TOF Invalid Valid
ON(1) OPERATION: Searching top is enabled
OFF (0) OPERATION: Searching top is disenabled
**This function is valid only on label models or black mark models.
** This function is invalid when thermal paper is selected on MSW4-4.