- 331 -
DLE DC4 fn d1...d7 (Specification of fn = 8)
CT-S280 CT-S300 CT-S2000 CT-S4000 BD2-2220 PMUseries
Supportmodel
CT-S281
CT-S310 CT-S801/851 CT-S601/651 CT-P29x series CT-S310II
[Function] Buffer clear
[Code] <10>H<14>H<fn><d1>…<d7>
[Range] fn=8,d1=1,d2=3,d3=20,d4=1,d5=6,d6=2,d7=8
[Outline] [The specification which is commontothemodel]
•Erasesalldata inreceiving buffer orprintbuffer.
•Sends thefollowing3-byte data group.
Hex. Decimal No. of Data
Header
37H 55
1byte
Identifier
25H 37
1byte
NULL
00H 0
1byte
•Entersthe state ofselectingSTANDARD MODE.
[Caution] [The specification which is commontothemodel]
•Whenreceivingacoderowcoincidingwiththecodeconfiguringthiscommand,the
sameoperationasthiscommandtakesplaceandattentionbytheuserisrequired.
Example:Whencorrespondingcoderowispresentinbitimagedata.
•Thiscommandmustnotbeusedbetweenothercommandcoderows.
Example:Thiscommandisusedinthebitimagedata.
•Thiscommandisignoredunderthefollowingconditions.
•Duringsendingblockdata