- 304 -
fn=49: Function 49 Setting Printing Density
GS ( K pL pH fn m
[Code] <1D>H<28>H<4B>H<pL><pH><fn><m>
[Range] (pL+pH×256)=2 (pL=2,pH=0)
fn=49
0≤m≤8, 250≤m≤255
[Default] m=0(Customized value settingvalue)
[Outline] [The specification which is commontothemodel]
•Sets printing density.
m Printing Density
250
Selects density level –6 (70%)
251
Selects density level –5 (75%)
252
Selects density level –4 (80%)
253
Selects density level –3 (85%)
254
Selects density level –2 (90%)
255
Selects density level –1 (95%)
0
Selects standarddensity (100%)
1
Selects density level +1(105%)
2
Selects density level +2(110%)
3
Selects density level +3(115%)
4
Selects density level +4(120%)
5
Selects density level +5(125%)
6
Selects density level +6(130%)
7
Selects density level +7(135%)
8
Selects density level +8(140%)