- 324 -
fn=80: Function 380 Storing 2D GS1 DataBar data to 2D code data storage area
GS ( k pL pH cn fn m n d1 dk
[Code] <1D>H<28>H<6B>H<pL><pH><cn><fn><m><n><d1dk>
[Range] 6(pL + pH×256)259 (0pL255pH0,1)
cn51
fn80
m48
n72,73,76
k(pLpH×256) 4
Range of d is different depending on type of GS1 Databar specified by n.
GS1 DataBar Stacked and GS1 DataBar Stacked Omnidirectional are same asGS1 DataBar
Omnidirectional.
GS1 DataBar Expanded Stacked is same as GS1 DataBar Expanded.
[Outline] [Thespecificationwhich is common to the model]
Stores 2-dimensional GS1 DataBar code data (d1…dk) to 2-dimensional code data storage
area.
n Barcode
72 GS1 DataBar Stacked
73 GS1 DataBar Stacked Omnidirectional
74 GS1 DataBar Expanded Stacked
fn=81: Function 381 Printing 2D GS1 Databar data in 2D code data storage area
GS ( k pL pH cn fn m
[Code] <1D>H<28>H<6B>H<pL><pH><cn><fn><m>
[Range] (pLpH×256)3 (pL3pH0)
cn51
fn81
m48
[Outline] [Thespecificationwhich is common to the model]
Prints GS1 DataBar code data stored in 2-dimensional code data storage area.