- 220 -
fn=4: Function 4 Sending the Set Memory Switch Value
GS ( E pL pH fn a
[Code] <1D>H<28>H<45>H<pL><pH><fn><a>
[Range] (pL+pH×256)=2
fn=4
CT-S280/BD2-2220
a=1, 2, 3
CT-S300
a=1, 2, 3, 4
CT-S281/CT-S310/CT-S2000/CT-S4000/PMU2XXX/PMU2XXXII
CT-P29x series
a=1, 2, 3, 4, 5
CT-S801/CT-S851/CT-S601/CT-S601/CT-S310II
a=1, 2, 3, 4, 5, 6
PMU2300III
a=1, 2, 3, 4, 5, 11, 12
[Outline] [The specification which is commontothemodel]
•Sends thecontent ofMSW set in “a”.
Hex. No.ofData
Header 37H 1
ID 21H 1
Data 30H or 31H 8
NULL 00H 1
•Sends theset value of data in8-byte data raw in order of bits 8, 7, 6
OFF: 30H (“0”)
ON: 31H(“1”)
[Caution] [The specification which depend on the model]
CT-S310/CT-S2000/CT-S4000/CT-S801/CT-S601
•MSW7 to MSW10 cannot be sent by this command.
•Transmission is available by <Sending preset customize value>.