GS ( E pL pH fn []
CT-S280 CT-S300 CT-S2000 CT-S4000 BD2-2220 PMUseries
Supportmodel
CT-S281
CT-S310 CT-S801/851 CT-S601/651 CT-P29x series CT-S310 II
[Function] Printer function setting command
[Outline] [The specification which is commontothemodel]
Printerfunctionsettingcommand isa command tochange the functionoftheprinterstoredon the
non-volatile memoryandexecutesthefunction setbythevalue offn.
Function No.
(fn)
Function
Function1
Transfers toprinter function settingmode.
Function2
Terminatesprinterfunction settingmode.
Function3
Sets memoryswitch value.
Function4
Sends memoryswitch value set.
Function5
Sets customize value.
Function6
Sends customized value set.
Function7
Copiesuser-defined page.
Function8
Definesthedata incolumn format tothecharacter code page of work area.
Function9
Definesthedata inrasterformat tothe character codepage ofworkarea.
Function10
Erases thedata ofcharactercode page ofworkarea.
Function11
Sets thecommunicationconditionof serialinterface. (Note)
Function12
Sends thecommunicationconditionof serialinterface set.
Function255
Sets allcontentssetinprinterfunction settingmode tothe stateat the time ofshipment.
pL, pH set the number of bytes following fn to (pL + pH×256).
Attheendofprinterfunctionsettingmode(Function2),resettingisexecuted.Thenthe inputbufferis cleared
to return various kindsof settingtothestateatthe time ofpower on.
Thesetvaluecanbeconfirmedwithouttransferringtoprinterfunctionsettingmodebyfunctions4,6,and12.
Other functions donot operate without transferring toprinterfunction setting mode.
[Caution] [The specification which is commontothemodel]
Thiscommandallowswriting tonon-volatile memory.Therefore, usingthis command frequently
may result inbreakageofmemory.Use this command appropriately [10times max./day] .
During executionof thiscommand,the printer isin Busystate and stops receiving operation. Therefore, data
transmissionfrom thehost is prohibited.

Table of Contents

Other manuals for Citizen CT-S280

Related product manuals