- 228 -
CT-S300
a=202: Controls input buffer full Busy with the value selected by
(nL+nH×256) and controls Busy with output/cancel timing
(remaining capacity).
When Input Buffer
Capacity “Small” is Set
When Input Buffer
Capacity 4K Bytes
(Large) is Set
(nL+nH×256)
Output Cancel Output Cancel
1 (Default) 16 26 128 256
2 16 40 128 512
3 30 50 72 256
4 30 60 72 512
XON/XOFF is also output by the establishment of conditions.
Ignores the data received when input buffer idle capacity is 0.
a=220: Sets the maximum width of black mark by the amount selected by
(nL+nH×256)
1(nL+nH×256)32767
Unit: 1 dot
Initial value: 40 dots
a=221: Sets the maximum length of black mark page with the value
selected by (nL+nH×256).
1(nL+nH×256)32767
Unit: 1 dot
Initial value: 2360 dots
a=222: Head margin set by the value selected by (nL+nH×256).
1(nL+nH×256)32767
Unit: 168dot
Initial value: 0dot
a=223: Sets black mark bottom margin with the amount selected by
(nL+nH×256).
1(nL+nH×256)255
Unit: 1 dot
Initial value: 34 dots
a=224: Sets cut distance with the value selected by (nL+nH×256).
1(nL+nH×256)255
Unit: 1 dot
Initial value: 232 dots
a=225: Sets head distance with the value selected by (nL+nH×256).
1(nL+nH×256)255
Unit: 1 dot
Initial value: 56 dots

Table of Contents