- 280 -
CT-S801/CT-S851
a=234:When LCD direction is specified
Setting Status Sending Data
Stored
Value
LCD direction
1st Byte
2nd
Byte
3rd Byte 4th Byte 5th Byte
1 Normal 49(“1”) - - - -
2 Inverted 50(“2”) - - - -
a=240:When buzzer volume is specified
Setting Status Sending Data
Stored
Value
Buzzer
volume
1st Byte
2nd
Byte
3rd Byte 4th Byte 5th Byte
1 Level 1 49(“1”) - - - -
2 Level 2 50(“2”) - - - -
3 Level 3 51(“3”) - - - -
4 Level 4 52(“4”) - - - -
a=241:When max dot number in 1 head division is specified
Setting Status Sending Data
Stored
Value
Dot number
1st Byte
2nd
Byte
3rd Byte 4th Byte 5th Byte
1 128 dots 49(“1”) - - - -
2 200 dots 50(“2”) - - - -
3 288 dots 51(“3”) - - - -
a=242:When Powered USB max dot number is specified
Setting Status Sending Data
Stored
Value
Dot number
1st Byte
2nd
Byte
3rd Byte 4th Byte 5th Byte
1 128 dots 49(“1”) - - - -
2 200 dots 50(“2”) - - - -
3 288 dots 51(“3”) - - - -
a=243:When Mechanism type is specified
Setting Status Sending Data
Stored
Value
Mechanism
type
1st Byte
2nd
Byte
3rd Byte 4th Byte 5th Byte
1 2 inch 49(“1”) - - - -
2 3 inch 50(“2”) - - - -

Table of Contents