Section 4 - Advanced WLAN Conguration
2. Enable or disable the security options as desired (refer to the table below), and click Save.
Field Description
Not Present in OUI Database
Test
This test checks whether the MAC address of the client is from a registered
manufacturer identied in the OUI database.
Not Present in Known Client
Database Test
This test checks whether the client, which is identied by its MAC address, is listed
in the Known Client Database and is allowed access to the AP either through the
Authentication Action of Grant or through the White List global action.
If the client is in the Known Client Database and has an action of Deny, or if the action
is Global Action and it is globally set to Black List, the client fails this test.
Congured Authentication Rate
Test
This test checks whether the client has exceeded the congured rate for transmitting
802.11 authentication requests.
Congured Probe Requests
Rate Test
This test checks whether the client has exceeded the congured rate for transmitting
probe requests.
Congured De-Authentication
Requests Rate Test
This test checks whether the client has exceeded the congured rate for transmitting
de‐authentication requests.
Maximum Authentication
Failures Test
This test checks whether the client has exceeded the maximum number of failed
authentications.
Authentication with Unknown
AP Test
This test checks whether a client in the Known Client database is authenticated with
an unknown AP.
Client Threat Mitigation
Select enable to send de‐authentication messages to clients that are in the Known
Clients database but are associated with unknown APs. The Authentication with
Unknown AP Test must also be enabled in order for the mitigation to take place.
Select disable to allow clients in the Known Clients database to remain authenticated
with an unknown AP.
Known Client Database Lookup
Method
When the controller detects a client on the network, it performs a lookup in the
Known Client database. Specify whether the controller should use the local or
RADIUS database for these lookups.
Known Client Database Radius
Server Name
If the known client database lookup method is RADIUS, this eld species the RADIUS
server name.
Rogue Detected Trap Interval
Specify the interval, in seconds, between transmissions of the SNMP trap telling the
administrator that rogue APs are present in the RF Scan database. If you set the value
to 0, the trap is never sent.
De-Authentication Requests
Threshold Interval
Specify the number of seconds an AP should spend counting the de‐authentication
messages sent by wireless clients.
De-Authentication Requests
Threshold Value
If the controller receives more than specied messages during the threshold interval
the test triggers.
Authentication Requests
Threshold Interval
Specify the number of seconds an AP should spend counting the authentication
messages sent by wireless clients.
Authentication Requests
Threshold Value
If the controller receives more than specied messages during the threshold interval
the test triggers.
Probe Requests Threshold
Interval
Specify the number of seconds an AP should spend counting the probe messages
sent by wireless clients.
Probe Requests Threshold Value
Specify the number of probe requests a wireless client is allowed to send during the
threshold interval before the event is reported as a threat.
Authentication Failure
Threshold Value
Specify the number of 802.1X authentication failures a client is allowed to have
before the event is reported as a threat.

Table of Contents

Other manuals for D-Link DWC-1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link DWC-1000 and is the answer not in the manual?

D-Link DWC-1000 Specifications

General IconGeneral
Ethernet LANYes
Wi-Fi standards802.11a, 802.11b, 802.11g
Networking standardsIEEE 802.1Q, IEEE 802.1x, IEEE 802.3, IEEE 802.3ad, IEEE 802.3u
Ethernet LAN data rates10, 100, 1000 Mbit/s
Number of managed Wi-Fi Access Points (max)6
Security algorithms3DES, DES, WEP, WPA, WPA2
USB 2.0 ports quantity2
Ethernet LAN (RJ-45) ports4
USB 3.2 Gen 1 (3.1 Gen 1) Type-A ports quantity0
CertificationFCC B, CE B, VCCI, C-tick, IC, cUL, LVD (EN60950-1)
Built-in displayNo
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Power requirementsDC 12V/2.5A
Power consumption (typical)19.3 W
Pallet width1200 mm
Pallet length1100 mm
Pallet height (air)1419 mm
Pallet height (sea)1847 mm
Pallet gross weight (air)415236 g
Pallet gross weight (sea)545648 g
Quantity per pallet (air)144 pc(s)
Quantity per pallet (sea)192 pc(s)
Shipping (inner) case width296 mm
Shipping (inner) case height428 mm
Shipping (inner) case length354 mm
Shipping (inner) case weight10826 g
Shipping (inner) case net weight10016 g
Number of cartons per pallet (air)36 pc(s)
Number of cartons per pallet (sea)48 pc(s)
Quantity per shipping (inner) case4 pc(s)
Weight and Dimensions IconWeight and Dimensions
Package depth396 mm
Package width273 mm
Package height80 mm
Package weight2504 g
Dimensions (WxDxH)280 x 180 x 44 mm