EasyManua.ls Logo

Fujitsu M10-4 - Starting the Entire System; Starting the System with an XSCF Command

Fujitsu M10-4
342 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
XSCF>
showhardconf
XSCF>
switchscf
-t
Standby
XSCF>
poweron
-p
0
XSCF>
poweron
-a
PPAR-IDs
to
power
on:00,01
Continue?
[y|n]
:
y
00
:
Powering
on
01
:
Powering
on
4.
Execute
the
showhardconf
command
to
check
the
hardware
configuration
and
the
status
of
each
FRU.
5.
If
the
state
of
the
master
chassis
requiring
maintenance
has
been
switched
to
the
standby
state
before
maintenance,
execute
the
switchscf
command
to
switch
the
chassis
to
the
mast er
XSCF.
6.
Execute
the
poweron
command
to
power
on
the
stopped
physical
partition.
In
the
following
example,
PPAR-ID
0
is
specified.
6.8 Starting
the
Entire
System
This
section
describes
the
procedure
for
starting
the
entire
system.
The
system
can
be
started
in
either
of
the
following
two
ways:
Starting
the
system
with
an
XSCF
command
Starting
the
system
from
the
operation
panel
6.8.1 Starting
the
system
with
an
XSCF
command
1.
Check
that
the
XSCF
STANDBY
LED
on
the
operation
panel
is
on.
2.
Log
in
to
the
XSCF
shell.
3.
Execute
the
poweron
command.
Enter
"y"
in
response
to
the
confirmation
message.
4.
Confirm
that
the
POWER
LED
on
the
operation
panel
is
on.
5.
Execute
the
showpp arstatus
command
to
confirm
that
the
power
to
all
the
physical
partitions
in
the
system
is
turned
on.
Fujitsu
M10-4/Fujitsu
M10-4S/SPARC
M10-4/SPARC
M10-4S
Service
Manual
November
2014108

Table of Contents