EasyManua.ls Logo

Fujitsu M10-4 - Restoring the Logical Domain to the Pre-Maintenance State

Fujitsu M10-4
342 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
unknown
c2::dsk/c2t50000394281B50C6d0
disk

connected
configured

unknown
c2::es/ses0

ESI

connected
configured

unknown
c2::smp/expd0

smp

connected
configured

unknown
c3

scsi-sas

connected
unconfigured
unknown
c4

scsi-sas

connected
unconfigured
unknown
c5

fc

connected
unconfigured
unknown
c6

fc

connected
unconfigured
unknown
c7

scsi-sas

connected
unconfigured
unknown

Omitted
#
cfgadm
-c
configure
<Ap_Id>
#
svcadm
disable
hotplug
3.
If
the
system
does
not
recognize
the
incorporated
internal
disk,
make
it
recognized
in
the
system.
a.
Execute
the
cfgadm
-c
configure
command
to
incorporate
the
target
internal
disk
into
the
logical
domain.
 
b.
With
the
cfgadm
-al
command,
check
the
status
of
the
internal
disk.
4.
If
you
have
enabled
the
hotplug
service,
execute
the
svcadm
command
to
disable
the
hotplug
service.
5. Assign
the
I/O
device
of
the
incorporated
internal
disk
to
the
logical
domain.
-
If
you
have
replaced
a
faulty
internal
disk,
proceed
to
"6.5.3
Restoring
the
logical
domain
to
the
pre-maintenance
state."
-
If
you
have
added
a
new
internal
disk,
perform
operations
according
to
the
description
in
"3.2.15
Configuring
an
I/O
device"
in
Fujitsu
M10/SPARC
M10
Systems
Domain
Configuration
Guide.
6.5.3 Restoring
the
logical
domain
to
the
pre-
maintenance
state
This
section
describes
the
flow
of
work
in
restoring
a
logical
domain
after
FRU
maintenance
to
the
pre-maintenance
state.
For
details
on
the
work
and
the
commands
used,
see
"3.2
Operations
and
Commands
Related
to
Logical
Domain
Configurations"
in
the
Fujitsu
M10/SPARC
M10
Systems
Domain
Configuration
Guide
and
Oracle
VM
Server
for
SPARC
3.1
Reference
Manual.
Fujitsu
M10-4/Fujitsu
M10-4S/SPARC
M10-4/SPARC
M10-4S
Service
Manual
November
2014102

Table of Contents

Related product manuals