Fujitsu M10-4 - Before Maintaining the PSU Backplane Unit;Operation Panel; Maintenance Precautions

Fujitsu M10-4
342 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(1)
Location
number Component
1 Operation
panel
(OPNL)
Figure
13-2
  
Location
of
the
operation
panel
13.2 Before
Maintaining
the
PSU
Backplane
Unit/Operation
Panel
This
section
describes
precautions
for
maintaining
the
PSU
backplane
unit
and
operation
panel
and
the
maintenance
flow.
13.2.1 Maintenance
precautions
This
section
describes
precautions
for
maintenance
on
the
PSU
backplane
unit
and
operation
panel
and
the
maintenance
flow.
Do
not
replace
a
PSU
backplane
unit
at
the
same
time
as
a
CPU
memory
unit.
If
you
replace
a
PSU
backplane
unit
at
the
same
time
as
a
CPU
memory
unit,
the
system
may
fail
to
operate
normally.
Replace
either
the
PSU
backplane
unit
or
the
CPU
memory
unit,
and
confirm
that
the
newly
installed
part
is
normal
by
using
the
showhardconf
or
showstatus
command.
Then,
replace
the
other
FRU.
Chapter
13
 
Maintaining
the
PSU
Backplane
Unit/Operation
Panel 269