*1
For
details,
see
"9.8.1
Installing
the
CPU
memory
unit
upper."
*2
For
details,
see
the
Fujitsu
M10/SPARC
M10
Systems
PCI
Card
Installation
Guide.
*3
For
details,
see
"A.2
SPARC
M10-4
Device
Paths"
or
"A.3
SPARC
M10-4S
Device
Paths"
in
the
Fujitsu
M10/SPARC
M10
Systems
System
Operation
and
Administration
Guide.
*1
For
details,
see
"9.8.1
Installing
the
CPU
memory
unit
upper."
Note
the
following
points
when
performing
internal
disk
installation:
To
expand
an
internal
disk,
remove
the
hard
disk
drive
filler
unit
from
the
slot
in
which
you
will
install
the
internal
disk.
Store
the
removed
filler
unit
in
a
safe
place
because
it
will
be
needed
if
you
subsequently
remove
the
internal
disk.
Note
the
following
points
when
performing
PCIe
card
installation:
Set
a
multipath
depending
on
the
use
of
the
PCIe
card
when
performing
active/hot
maintenance
or
active/cold
maintenance
with
PHP.
For
active
addition
by
PHP,
confirm
that
the
card
is
PHP
supported.
To
do
so,
check
"Appendix
A
Cards
that
Support
PCI
Hot
Plug
and
Dynamic
Reconfiguration"
in
the
Fujitsu
M10/SPARC
M10
Systems
PCI
Card
Installation
Guide.To
perform
active
addition
using
PHP
combined
with
dynamic
SR-IOV
and
the
dynamic
reconfiguration
function
of
PCIe
end
point
devices,
check
the
applicable
cards
by
referring
to
"Appendix
B
Cards
that
Support
SR-IOV"
or
"Appendix
D
Cards
that
support
the
dynamic
reassignment
function
for
the
PCIe
end
point
device
(PCIe
card)"
in
the
same
manual.
When
performing
PCIe
card
installation,
remove
the
filler
for
the
PCIe
card
from
the
PCIe
card
cassette.
Store
the
removed
filler
in
a
safe
place
because
it
will
be
needed
if
you
subsequently
remove
the
PCIe
card.
4.3.3 Precautions
for
removal
Note
the
following
points
when
performing
CPU
memory
unit
upper
or
memory
removal:
When
removing
a
CPU
memory
unit
upper,
mount
the
stored
filler
unit
after
removing
the
CPU
memory
unit
upper.
Remove
the
shortest
PCIe
cable
that
connects
the
CPU
memory
unit
upper
and
CPU
memory
unit
lower.
However,
you
do
not
need
to
remove
the
three
PCIe
cables
that
are
connected
to
the
CPU
memory
unit
lower.
Removal
of
the
CPU
memory
unit
upper
in
a
system
where
the
I/O
bus
was
reconfigured
eliminates
the
root
complex
used
in
the
CPU
memory
unit
upper.
Also,
some
PCIe
slots
can
no
longer
be
used.
To
enable
use
of
the
PCIe
slots,
"activate"
the
I/O
bus
reconfiguration
function
(*1)
.
However,
the
I/O
device
path
changes
as
a
result,
so
you
may
need
to
reconfigure
the
logical
domains.
Observe
the
memory
installation
rules
when
you
remove
memory.
For
details,
see
"2.2.1
Memory
installation
rules."
Note
the
following
point
when
you
perform
internal
disk
removal:
When
removing
an
internal
disk,
remove
the
internal
disk
and
then
mount
the
Fujitsu
M10-4/Fujitsu
M10-4S/SPARC
M10-4/SPARC
M10-4S
Service
Manual
November
201450

Table of Contents