CPU
clocks.
Note
the
following
point
when
replacing
a
PCIe
card:
For
active
maintenance
by
PHP,
a
multipath
setting
is
necessary
depending
on
the
use
of
the
PCIe
cards.
For
active
maintenance
by
PHP,
confirm
that
the
card
is
PHP
supported.
To
do
so,
check
"Appendix
A
Cards
that
Support
PCI
Hot
Plug
and
Dynamic
Reconfig uratio n "
in
the
Fujitsu
M10/SPARC
M10
Systems
PCI
Card
Installation
Guide.To
perform
active
replacement
using
PHP
combined
with
dynamic
SR-IOV
and
the
dynamic
reconfiguration
function
of
PCIe
end
point
devices,
check
the
applicable
cards
by
referring
to
"Appendix
B
Cards
that
Support
SR-IOV"
or
"Appendix
D
Cards
that
support
the
dynamic
reassignment
function
for
the
PCIe
end
point
device
(PCIe
card)"
in
the
same
manual.
Note
the
following
points
when
replacing
the
operation
panel:
To
replace
the
operation
panel,
remove
the
PSU
backplane
from
the
chassis.
To
replace
the
operation
panel,
set
the
BB-ID
of
the
replacement
operation
panel
to
the
same
value
as
that
before
replacement.
4.3.2 Precautions
for
installation
Note
the
following
points
when
performing
CPU
memory
unit
upper
or
memory
installation:
When
installing
a
CPU
memory
unit
upper,
remove
the
filler
unit.
Store
the
removed
filler
unit
in
a
safe
place
because
it
will
be
needed
if
you
subsequently
remove
the
CPU
memory
unit
upper.
If
PCI
Express
cables
are
not
connected
to
the
CPU
memory
unit
lower,
you
need
to
add
PCI
Express
cables.
If
PCI
Express
cables
are
connected
to
the
CPU
memory
unit
lower,
you
need
to
add
only
one
PCI
Express
cable.
If
the
CPU
memory
unit
upper
for
the
2CPU
configuration
of
the
SPARC
M10-4/M10-4S
is
installed,
the
root
complex
is
also
installed.
Then,
due
to
the
I/O
bus
reconfiguration
function
(*1)
,
the
I/O
bandwidth
increases,
and
the
PCIe
card
installation
rules
(*2)
change.
In
addition,
the
I/O
bus
reconfiguration
also
changes
the
device
path
of
the
I/O
device
(*3)
,
so
you
may
have
to
reconfigure
the
logical
domains.
The
type
of
CPU
memory
unit
varies
depending
on
the
number
of
CPU
clocks.
They
cannot
be
mixed
in
the
same
device,
but
they
can
be
mixed
in
a
system
with
a
building
block
configuration.
Observe
the
memory
installation
rules
when
you
expand
memory.
For
details,
see
"2.2.1
Memory
installation
rules."
When
you
expand
memory
by
64
GB,
apply
XCP
2090
or
later.
Chapter
4
 
Preparation
and
Precautions
for
Maintenance 49