unit,
or
memory:
■
Do
not
replace
the
CPU
memory
unit
lower
at
the
same
time
as
the
PSU
backplane
unit.
If
you
replace
both
the
CPU
memory
unit
lower
and
the
PSU
backplane
unit
at
the
same
time,
the
system
may
fail
to
operate
normally.
Either
of
the
XSCF
unit
mounted
in
the
CPU
memory
unit
lower
or
the
PSU
backplane
unit
must
remain
mounted,
since
they
store
device
identification
information.
Replace
either
of
the
CPU
memory
unit
lower
and
PSU
backplane
unit,
and
confirm
that
the
replacement
part
operates
normally
by
executing
the
showhardconf
or
showstatus
command.
Then,
replace
the
other
FRU.
■
When
remounting
memory
in
the
work
of
replacing
the
CPU
memory
unit
or
memory,
be
sure
remount
the
memory
in
same
location
as
that
before
replacement.
■
The
weight
of
the
CPU
memory
unit
is
17
kg
(37.4
lb).
If
the
mounting
location
in
the
rack
is
24U
or
higher,
be
sure
that
two
people
perform
the
work.
If
you
attempt
to
perform
the
maintenance
work
alone,
you
may
injure
yourself
or
cause
damage
to
the
chassis.
■
To
use
the
hardware
RAID
function,
after
replacing
the
CPU
memory
unit
lower,
you
need
to
reactivate
the
hardware
RAID
volume.
For
details,
see
"14.2.11
Re-enabling
a
hardware
RAID
volume"
in
the
Fujitsu
M10/SPARC
M10
Systems
System
Operation
and
Administration
Guide.
■
Before
replacing
the
CPU
memory
unit
lower,
execute
the
dumpconfig
command
to
save
the
system
setting
information.
If
you
replace
the
CPU
memory
unit
lower,
the
CPU
Activation
setting
information
and
CPU
Activation
key
may
be
erased.
To
return
the
CPU
Activation
setting
information
and
CPU
Activation
key
to
their
original
states,
execute
the
restoreconfig
command
to
restore
the
CPU
Activation
setting
information
and
CPU
Activation
key
saved
beforehand
using
the
dumpconfig
command.
For
details,
see
"10.10
Saving/Restoring
XSCF
Setting
Information"
in
the
Fujitsu
M10/SPARC
M10
Systems
System
Operation
and
Administration
Guide.
■
If
you
switch
the
microSD
card
when
replacing
the
CPU
memory
unit
lower,
the
maintenance
time
is
shorter
since
the
XSCF
setting
information
is
inherited.
A
check
of
the
XCP
firmware
version
after
diagnosis
of
the
system
board
may
find
that
the
CMU
firmware
versions
do
not
match
between
the
current
XCP
and
reserve
XCP.
However,
this
does
not
affect
system
operation.
If
you
start
the
system
when
the
current
and
reserve
XCPs
have
been
switched,
the
CMU
firmware
stored
on
the
microSD
card
is
automatically
applied.
Note
the
following
points
when
replacing
a
power
supply
unit
or
fan
unit:
■
The
power
supply
units
and
cooling
fans
have
redundant
configurations.
The
system
can
operate
even
if
one
power
supply
unit
or
one
cooling
fan
in
a
fan
unit
experiences
a
failure.
However,
avoid
operating
the
system
with
a
faulty
power
supply
unit
or
a
faulty
cooling
fan
in
one
of
the
fan
units
for
an
extended
period.
Replace
the
unit
containing
the
faulty
power
supply
or
faulty
fan.
■
When
replacing
multiple
power
supply
units
or
fan
units,
replace
one
unit
at
a
time.
If
redundancy
of
the
power
supply
units
or
fan
units
cannot
be
secured,
perform
maintenance
with
the
system
stopped.
■
Do
not
force
the
power
supply
unit
or
fan
unit
into
its
slot.
Using
excessive
force
may
damage
the
FRU
and
chassis.
■
The
type
of
power
supply
unit
or
fan
unit
varies
depending
on
the
number
of
Fujitsu
M10-4/Fujitsu
M10-4S/SPARC
M10-4/SPARC
M10-4S
Service
Manual
・
November
201448