XSCF>
ioxadm
env
-te
PCIBOX#2008
Location

Sensor

Value
Resolution
Units
PCIBOX#2008

AIRFLOW

180.000

0.000
CHM
PCIBOX#2008

P_CONSUMPTION

68.000

0.000
W
PCIBOX#2008/PSU#0

FAN

3936.000

0.000
RPM
PCIBOX#2008/PSU#1

FAN

3584.000

0.000
RPM
PCIBOX#2008/FAN#0

FAN

3374.000

0.000
RPM
PCIBOX#2008/FAN#1

FAN

3374.000

0.000
RPM
PCIBOX#2008/FAN#2

FAN

3374.000

0.000
RPM
PCIBOX#2008/IOBT

T_INTAKE

26.000

0.000
C
PCIBOX#2008/IOBT

T_PART_NO 0

31.500

0.000
C
PCIBOX#2008/IOBT

T_PART_NO 1

30.750

0.000
C
PCIBOX#2008/IOBT

T_PART_NO 2

31.500

0.000
C
PCIBOX#2008/IOBT

V_12_0V

12.069

0.000
V
PCIBOX#2008/IOBT

V_3_3_NO0

3.293

0.000
V
PCIBOX#2008/IOBT

V_3_3_NO1

3.295

0.000
V
PCIBOX#2008/IOBT

V_3_3_NO2

3.291

0.000
V
PCIBOX#2008/IOBT

V_3_3_NO3

3.300

0.000
V
PCIBOX#2008/IOBT

V_1_8V

1.804

0.000
V
PCIBOX#2008/IOBT

V_0_9V

0.900

0.000
V
Checking
the
status
of
a
PCI
expansion
unit
If
a
PCI
expansion
unit
is
connected,
execute
the
ioxadm
command
from
the
XSCF
shell
to
check
the
status
of
the
PCI
expansion
unit.
-
ioxadm
command
Execute
the
ioxadm
command
to
check
the
environmental
conditions
(temperature,
voltage,
etc.)
or
LED
indications
for
the
PCI
expansion
unit.
1.
Log
in
to
the
XSCF
shell.
2.
Execute
the
ioxadm
command
to
check
the
environmental
conditions
of
the
specified
PCI
expansion
unit.
To
specify
a
PCI
expansion
unit,
enter
the
serial
number
of
the
PCI
expansion
unit
after
determining
it
by
executing
the
ioxadm
list
command.
The
following
example
shows
the
environmental
conditions
for
the
PCIBOX#2008
"2008"
are
the
last
four
digits
of
the
serial
number
of
the
PCI
expansion
unit.
Checking
log
information
Execute
the
showlogs
command
to
check
error
log
information.
1.
Log
in
to
the
XSCF
shell.
2.
Execute
the
showlogs
command
to
check
the
log
information.
The
log
information
is
listed
in
the
order
of
date,
with
the
oldest
appearing
first.
The
following
example
shows
that
an
Alarm
status
occurred
in
PSU#1
and
PSU#2
at
12:45:31
on
Oct
20,
the
Alarm
status
changed
to
a
Warning
status
at
Fujitsu
M10-4/Fujitsu
M10-4S/SPARC
M10-4/SPARC
M10-4S
Service
Manual
November
201444

Table of Contents