FRU-Part-Number:CA07361-D202
A1

;

+
Power_Supply_System:
;

+
Memory_Size:256
GB;

CMUL
Status:Normal;
Ver:0101h;
Serial:PP123001Y1

;

*
BB#00
CMUL
serial

+
FRU-Part-Number:CA07361-D941
C3

/7060911

;

+
Memory_Size:128
GB;
Type:
A
;

CPU#0
Status:Normal;
Ver:4142h;
Serial:00321144;

+
Freq:3.000
GHz;
Type:0x10;

+
Core:16;
Strand:2;

CPU#1
Status:Normal;
Ver:4142h;
Serial:00322957;

+
Freq:3.000
GHz;
Type:0x10;

+
Core:16;
Strand:2;
------------------------
Omitted
------------------------

BB#01
Status:Normal;
Role:Standby;
Ver:2044h;
Serial:2081230011;

+
FRU-Part-Number:CA07361-D202
A1

;

+
Power_Supply_System:
;

+
Memory_Size:256
GB;

CMUL
Status:Normal;
Ver:0101h;
Serial:PP123203N0

;

*
BB#01
CMUL
serial

+
FRU-Part-Number:CA07361-D941
C3

/7060911

;

+
Memory_Size:128
GB;
Type:
A
;

CPU#0
Status:Normal;
Ver:4142h;
Serial:00320804;

+
Freq:3.000
GHz;
Type:0x10;

+
Core:16;
Strand:2;

CPU#1
Status:Normal;
Ver:4142h;
Serial:00321030;

+
Freq:3.000
GHz;
Type:0x10;

+
Core:16;
Strand:2;

MEM#00A
Status:Normal;

+
Code:2c800118KSF1G72PZ-1G6E1
4531-1A94229F;

+
Type:04;
Size:8
GB;
------------------------
Omitted
-----------------------
#
diskinfo
D:devchassis-path

c:occupant-compdev
-----------------------------------------------------------
------------------
/dev/chassis/SYS/BB0/CMUL/HDD0

-
/dev/chassis/SYS/BB0/CMUL/HDD1

-
/dev/chassis/SYS/BB0/CMUL/HDD2

-
/dev/chassis/SYS/BB0/CMUL/HDD3

-
2.
Execute
the
diskinfo
command
to
confirm
the
physical
disk
slot.
(1)
to
(4)
in
the
example
below
specify
the
following:
(1):
The
device
path
name
and
logical
path
name
of
the
disk
mounted
on
the
HDD0
of
BB#01.
(2):
The
device
path
name
and
logical
path
name
of
the
disk
mounted
on
the
HDD1
of
BB#01.
(3):
The
device
path
name
and
logical
path
name
of
the
disk
mounted
on
the
HDD0
of
BB#00.
(4):
The
device
path
name
and
logical
path
name
of
the
disk
mounted
on
the
HDD1
of
BB#00.
Chapter
5
 
Preparations
Required
for
Maintenance 65

Table of Contents