EasyManua.ls Logo

Fujitsu M10-4 - Page 88

Fujitsu M10-4
342 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
XSCF>
poweroff
-a
PPAR-IDs
to
power
off:00,01,02
Continue?
[y|n]
:
y
00
:
Powering
off
01
:
Powering
off
02
:
Powering
off
Note
-
The
order
in
which
guest
domains
shut
down
depends
on
the
shut-down
group
setting
of
Oracle
VM
Server
for
SPARC.
Note
-
For
a
building
block
configuration,
check
the
POWER
LEDs
on
all
the
chassis
that
make
up
the
system.
XSCF>
showpparstatus
-a
PPAR-ID
PPAR
Status
00
Powered
Off
01
Powered
Off
02
Powered
Off
XSCF>
showdomainstatus
-p
0
Logical
Domain
Name
Status
primary
Solaris
powering
down
4S-159-D0-G0
Solaris
powering
down
4S-159-D0-G1
Solaris
powering
down
4S-159-D0-G2
Solaris
powering
down
The
following
processes
are
performed.
-
Oracle
Solaris
is
completely
shut
down.
-
The
system
stops
and
enters
the
POWERON
READY
state
(The
XSCF
is
running).
4.
Check
that
the
POWER
LED
on
the
operation
panel
is
off.
5.
Execute
the
showpp arstatus
command
to
confirm
that
the
power
to
the
physical
partition
is
turned
off.
In
the
following
example,
[PPAR
Status]
displays
"Powered
Off"
for
PPAR-IDs
00,
01,
and
02,
indicating
that
the
power
to
all
the
physical
partitions
has
been
turned
off.
6.
Execute
the
showdo mainstatus
command
to
check
the
operating
condition
of
the
logical
domain.
In
the
following
example,
[Status]
displays
"Solaris
powering
down"
for
the
logical
domains,
indicating
that
Oracle
Solaris
is
shutting
down.
Fujitsu
M10-4/Fujitsu
M10-4S/SPARC
M10-4/SPARC
M10-4S
Service
Manual
November
201474

Table of Contents