Preliminary steps
"Locating the defective server" on page 43
.
"Verifying the system time settings" on page 84.
"Shutting down the server" on page 45.
"Disconnecting the power cord" on page 46.
"Getting access to the component" on page 47.
Replacing the defective CMOS battery
1
2
3
4
Figure 253: Replacing the CMOS battery
Press the locking spring into direction of the arrow (1), so that the CMOS
battery jumps out of its socket.
Remove the CMOS battery (2).
CAUTION
Sharp tools such as screw drivers might damage system board
components in case of slipping.
If the CMOS battery cannot be ejected without the help of a tool,
it is recommended to use a tooth pick.
Insert a new CMOS battery of the same type into the socket (3) and (4).