EasyManua.ls Logo

Fujitsu PRIMERGY RX2520 M5

Fujitsu PRIMERGY RX2520 M5
508 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A - Identification
Status Description
blue on
The server has been highlighted using iRMC web
interface or the ID button on the front panel for easy
identification.
flashing blue
The server has been highlighted for easy
identification using the iRMC (A
VR) with disabled
local VGA output.
B - CSS (Customer Self Service)
Status Description
off No critical event detected (CSS component).
orange on Prefailure event detected (CSS component).
flashing orange CSS component failure detected.
C - GEL (Global Error LED)
Status Description
off No critical event detected (non-CSS component).
orange on Prefailure event detected (non-CSS component).
flashing orange
Non-CSS component failure detected.
Possible causes:
System is out of the specified temperature range
Defective sensor
CPU error
Error detected by server management software
Appendix A
440 Upgrade and Maintenance Manual RX2520 M5

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2520 M5

Related product manuals