Configuring a history entry
1. Select Device > RMON from the navigation tree.
2. Click the History tab.
Figure 82 History entry
3. Click Add.
Figure 83 Adding a history entry
4. Configure a history entry as described in Table 25.
5. Click Apply.
Table 25 Configuration items
Item Descri
p
tion
Interface Name Select the name of the interface on which the history entry is created.
Buckets Granted
Set the capacity of the history record list corresponding to this history entry (the
maximum number of records that can be saved in the history record list).
If the current number of the entries in the table has reached the maximum
number, the system deletes the earliest entry to save the latest one. The statistics
include total number of received packets on the current interface, total number
of broadcast packets, and total number of multicast packets in a sampling
period.
Interval Set the sampling period.
Owner Set the owner of the entry.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 1920 Gigabit Ethernet Switch Series and is the answer not in the manual?

HP 1920 Gigabit Ethernet Switch Series Specifications

General IconGeneral
BrandHP
Model1920 Gigabit Ethernet Switch Series
CategorySwitch
LanguageEnglish

Related product manuals