NOTICE
INCORRECT HOSES, CONNECTIONS, OR FITTINGS CAN CAUSE DAMAGE AND BAD
PERFORMANCE
Noncompliant hoses, hose connections, or hose fittings can crack or leak. Incorrect fittings can
cause malfunctions with the internal valves because contaminants can enter the valves through
damaged or loose fittings.
All hoses, hose connections, and hose fittings used for supply-gas plumbing must be designed
for use with the appropriate gas and pressure rating. NEVER connect a supply gas to a hose,
connection, or fitting that is not designed for that gas type or pressure. A replacement hose,
connection, or fitting must meet all applicable regulations and codes.
NOTICE
INCORRECT SUPPLY-GAS FITTINGS CAN CAUSE VALVES TO MALFUNCTION
If you alter or replace the fittings, it can cause the internal valves to malfunction if particulates get
inside.
Do not change or replace the supply-gas fittings on the gas connect console.
NOTICE
INCORRECT SUPPLY-GAS CONNECTIONS CAN CAUSE CUTTING SYSTEM DAMAGE
Incorrect connections can reduce the life of consumables and cause damage to the torch head,
torch receptacle, torch leads, and torch connect console.
NEVER connect a supply gas to a hose, connection, or fitting that is not designed for that gas type
or pressure.