KRONE ISOBUS-Terminal CCI 100
99
Pos: 22.91 /BA/Inf o-Center/CCI-I SOBUS-Terminal/CCI-BiG Pac k/Hauptmenüs/Haup tmenü 1 Einstellungen/ Menü 1-6 „Ballenwaage“ T2 justieren @ 109\mod_1335 353555144_78.docx @ 976 146 @ @ 1
6.10.9.1 Adjusting the Bale Balance
The bale balance can be readjusted in the limit range from 95% to 105%
To do this:
• Stop the machine
• Fit a calibrated sample weight (250 to 300 kg) onto the empty bale balance
Readjust the bale balance if the display value (2) in the display deviates from the sample
weight
To do this:
• Change value (1) via function key
or until the value (2) corresponds to the weight
of the sample weight (the symbol
in the upper line goes out)
Note
If the limit range is not sufficient to adjust the bale balance, please contact the customer
service.
• Press function key
, the set value is saved, the symbol in the upper line appears
• Pressing the function key
closes the called up menu
• Pressing the function key
and holding it down brings up the basic screen
Pos: 22.92 /BA/Inf o-Center/CCI-I SOBUS-Terminal/CCI-BiG Pac k/Hauptmenüs/Haup tmenü 1 Einstellungen/ Menü 1-6 „Ballenwaage“ T3 Nullen @ 111\mod_13370060337 53_78.docx @ 989762 @ 2 @ 1
6.10.9.2 Zeros
“Zero” the force sensor if no bale (weight) is on the bale balance but a value is displayed in line
(2)
Note
Resetting (zeros) may only be made if the bale balance is without load.
• Set the force sensor back to zero by pressing the function key
Pos: 22.93 /BA/--- ------------ Seitenumbruch------ ---------- @ 0\mod_119617 5311226_0.doc x @ 4165 @ @ 1