1 Switch
14.5.10 Exchanging the suction gripper
Precondition
• The robot controller is switched off and secured to prevent unauthor-
ized persons from switching it on again.
Procedure
1. Remove the spiral hose from the gripper.
2. Fasten the new gripper to the spiral hose using a plug connection.
14.5.11 Exchanging the camera
Precondition
• The robot controller is switched off and secured to prevent unauthor-
ized persons from switching it on again.
Procedure
1. Unplug the cable.
2. Remove 2 M3x6-8.8 screws from the camera.
3. Fasten the new camera with 2 M3x6-8.8 screws.
4. Plug in the cable.
ready2_educate
BA ready2_educate V8 | Issued: 05.09.2018 www.kuka.com | 135/154