3.4.5 Mounting plate, pneumatic system
Description
The service unit supplies the gripper with compressed air. The operating
pressure for the gripper can be set using the pressure regulating valve.
The shut-off valve is used for locking and unlocking the service unit.
The pneumatic system mounting plate may vary according to the
ready2_educate variant.
Setting:
Operating pressure: 6 bar
Fig. 3-22: Mounting plate, pneumatic system
1 Shut-off valve
2 Pressure regulating valve
3 Multiple distributor
4 Solenoid valve
5 Service unit
6 Pressure gauge
7 Filter unit
8 Condensate drainage screw
ready2_educate