5.2 Safety functions
5.2.1 EMERGENCY STOP device
An EMERGENCY STOP device is located on the control panel and on the
smartPAD. If the EMERGENCY STOP device is pressed, the drives are
deactivated immediately in operating modes T1 and T2 and the robot
stops with a STOP 0. In the Automatic operating modes, the drives are
deactivated after 1 s and the robot stops with a STOP 1. The gripper
changes its status if an EMERGENCY STOP or operator safety is trig-
gered.
The EMERGENCY STOP device must be pressed as soon as persons or
equipment are endangered. Before operation can be resumed, the EMER-
GENCY STOP device must be turned to release it.
Fig. 5-1: EMERGENCY STOP device
1 EMERGENCY STOP device on the smartPAD
2 EMERGENCY STOP device on the control panel
NOTICE
If the operator leaves the training cell, he must lock the touch panel,
actuate the EMERGENCY STOP device on the control panel and store
the key for the EMERGENCY STOP securely.
5.2.2 Safety door switches
The safety door switches are used to monitor whether the safety doors of
the ready2_educate cell are closed. If a safety door is opened during au-
tomatic operation, the robot drives are switched off and the robot stops
with a STOP 0. The gripper changes its status if an EMERGENCY STOP
or operator safety is triggered.
The cell may only be opened in T1 mode.
The cell cannot be operated in T2 mode with a safety door open. The
following warning message is issued:
• Moving the robot in T2 mode with a safety door of the training cell
open is not permitted. Close the safety door and acknowledge to
continue.