9.2.2 Installing or updating ready2_educate_advanced
Description
ready2_educate_advanced is installed in WorkVisual and added to the
project. During project deployment, the option package is automatically in-
stalled on the robot controller.
In the case of an update, the previous version of the option package in
WorkVisual must first be uninstalled.
As standard, the software is already installed.
It is advisable to archive all relevant data before updating a software
package.
Precondition
• User group “Expert”
• T1 or T2 mode
• No program is selected.
• Network connection between PC and robot controller
• The KOP file of the software to be installed
• ready2_educate is installed
• Gripper is configured
• Profinet KRC-Nexxt is installed
Procedure
1. Only for an update: Uninstall the previous version of the ready2_edu-
cate_advanced option package in WorkVisual.
2. Install the ready2_educate_advanced option package in WorkVisual.
3. Load the project from the robot controller.
4. Insert the ready2_educate_advanced option package into the project.
5. Only for initial installation:
Inserting the CPU configuration:
If the controller is inactive, PLC configuration must be inserted into
the project structure.
All the required I/O presets relating to connection of the CPU and the
robot controller have now been made.
6. Once this file is loaded, the project can be transferred to the controller.
7. Confirm the changes with Yes. The robot controller carries out a re-
boot.
Information about procedures in WorkVisual is contained in the WorkVi-
sual documentation.