LOG file
A LOG file is created under C:\KRC\ROBOTER\LOG.
9.2.3 Uninstalling ready2_educate_advanced
It is advisable to archive all relevant data before uninstalling a software
package.
Precondition
• User group “Expert”
• T1 or T2 mode
• No program is selected.
• Network connection between PC and robot controller
Procedure
1. Load the project from the robot controller.
2. Remove the CPU configuration PLC configuration from the project
structure.
3. Remove the ready2_educate_advanced option package from the
project. A window with modifications is displayed.
4. Deploy the project from WorkVisual to the robot controller and activate
it.
5. Answer the request for confirmation Do you want to activate the
project […]? with Yes.
6. An overview with the changes and a request for confirmation are dis-
played on the smartHMI. Answer this with Yes. The option package is
uninstalled and the robot controller carries out a reboot.
Information about procedures in WorkVisual is contained in the WorkVi-
sual documentation.
LOG file
A LOG file is created under C:\KRC\ROBOTER\LOG.
9.3 ready2_educate_vision installation
9.3.1 System requirements, ready2_educate_vision
Hardware
• KR C4 compact
Software
• KUKA System Software 8.3.x
• GripperSpotTech 4.0.x
• WorkVisual 4.0.x
• ready2_educate
• VisionTech 4.0.x
The number of the required release must be taken from the file Release-
Notes_[…].txt. The file is located on the data storage medium with the rel-
evant software.
ready2_educate
BA ready2_educate V8 | Issued: 05.09.2018 www.kuka.com | 97/154
Installation