Mains frequency 50 Hz…60 Hz ± 1 Hz
Rated connected load 2 kVA
Mains-side fusing 2x 16 A slow-blowing (1 (2)x phase; 1x neutral
conductor (optional))
Thermal power dissi-
pation of robot con-
troller
max. 400 W
Equipotential bonding The common neutral point for the equipotential
bonding conductors and all protective ground
conductors is the reference bus of the power
unit.
Air connection
Air connection Compressed air, oil-free:
dry; filtered (max. particle size 0.01 mm); min.
operating pressure 6 bar
Environmental conditions
Operation +5 °C +40 °C (278 K to 313 K)
Temperature change max. 1.1 K/min
Storage and transpor-
tation
-5 °C +40 °C (268 K to 313 K)
Humidity rating Humidity class
3k3 according to EN 60721-3-3; 1995
Altitude Without derating
up to 1000 m above mean sea level
With derating 5%/1000 m
1000 m 4000 m above mean sea level
Vibration resistance
Type of loading
During trans-
portation
During continuous
operation
r.m.s. acceleration (sus-
tained oscillation)
0.37 g 0.1 g
Frequency range (sus-
tained oscillation)
4...120 Hz 4...120 Hz
Acceleration (shock in
X/Y/Z direction)
10 g 2.5 g
Waveform/duration (shock
in X/Y/Z direction)
Half-sine/11 ms Half-sine/11 ms
Further information is contained in the operating and assembly instruc-
tions for the manipulator.
Further information is contained in the operating instructions for the ro-
bot controller.
ready2_educate
BA ready2_educate V8 | Issued: 05.09.2018 www.kuka.com | 63/154
Technical data

Table of Contents