Function Description
float cos(float x) Calculates cos(x) (x in radians)
float tan(float x) Calculates tan(x) (x in radians)
float asin(float x) Calculates asin(x) (x in radians)
float acos(float x) Calculates acos(x) (x in radians)
float atan(float x) Calculates atan(x) (x in radians)
float pow (float x, float y) Calculates the exponential value. x is the base, y is the exponent
float fabs(float x) Calculates the absolute value of x
Example: Accumulated Volume
The following example shows how to create a custom measurement that is based on the values from
other measurements and persistent values. The example calculates the volume of the target using a
series of box area measurement values.
/* Calculate the volume of an object by accumulating the boxArea measurements*/
/* Encoder Resolution is 0.5mm. */
/* BoxArea Measurement ID is set to 1*/
long long encoder_res = 500;
long long Volume = Memory_Get64s(0);
Memory_Set64s(0, Volume);
if (Volume > 1000000)
{
Output_Set(Volume, 1);
}
else
{
Output_Set(Volume, 0);
}

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Master 800 and is the answer not in the manual?

LMI Technologies Master 800 Specifications

General IconGeneral
BrandLMI Technologies
ModelMaster 800
CategoryAccessories
LanguageEnglish

Related product manuals