Gocator Line Profile Sensors: User Manual
Protocols • 465
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4103).
status 32s 6
Reply status. For a list of status codes, see Commands on page
446.
Reply
Clear Alignment
The Clear Alignment command clears sensor alignment.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4102).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4102).
status 32s 6
Reply status. For a list of status codes, see Commands on page
446.
Reply
Get Timestamp
The Get Timestamp command retrieves the sensor's timestamp, in clock ticks. All devices in a system are
synchronized with the system clock; this value can be used for diagnostic purposes, or used to
synchronize the start time of the system.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x100A).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x100A).
status 32s 6
Reply status. For a list of status codes, see Commands on page
446.
timestamp 64u
10
Timestamp, in clock ticks.
Reply
Get Encoder
This command retrieves the current system encoder value.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Master 800 and is the answer not in the manual?

LMI Technologies Master 800 Specifications

General IconGeneral
BrandLMI Technologies
ModelMaster 800
CategoryAccessories
LanguageEnglish

Related product manuals